ONE OF UKRAINE''S BIGGEST CHALLENGES FOR 2025 FIBER

Low-loss liquid-cooled power supply 2025 model

Low-loss liquid-cooled power supply 2025 model

Key features of the showcase include complete power solutions for both 800 VDC and ±400 VDC power architectures, the newly-launched liquid-to-liquid (L2L) CDU with 2,000kW of cooling capacity for new AI data centers, the new 300kW liquid-to-air (L2A) CDU for. , October 6th, 2025 — Delta, a global leader in power management and smart green solutions, will present its next-generation of highly integrated high-voltage DC power distribution, advanced precision cooling, and networking solutions for AI data centers at the OCP Global Summit. The iHP20S Liquid Cooled precision AC-DC configurable power supply is 100% digitally controlled in a 757. 8 mm package and provides eight individual slots that accept intelligent DC-DC converter modules. Its cooling is handled by the PC's custom liquid cooling setup, which means that. The PSU channels coolant through heatsinks that come into contact with the hottest components, such as switching MOSFETs, Schottky diodes, APFC, IGBTs, and more.

Read More
Reasons for fiber optic patch cord not communicating

Reasons for fiber optic patch cord not communicating

The Most Common Causes of Fiber Optic Failure: Usually, you'll find that if you have no connection at all, it is because of a broken cable. If you think you know which cable is bad, there is a quick and easy test you can do yourself with a laser pointer or bright flashlight. Fiber optic patch cords are often treated as low-risk consumables, yet a large percentage of optical link failures originate at the patch cord level. While this was only a minor issue, it greatly affected both the optical alignment and, as indicated by test results in the field, return loss, which ideally should be approximately -65 dB, increased to 20 dB or more because of light reflecting into transceiver modules. These seemingly simple cables are the lifeline of your high-speed connection, but poor quality, damaged, or improperly installed patch cords can cause frequent disconnections, signal loss, and degraded network performance. Fiber optic troubleshooting is an essential skill for network administrators, technicians, and engineers responsible for maintaining and repairing fiber optic systems. This guide dives deep into the most prevalent fiber optic network problems, their root causes, and actionable solutions.

Read More
What to do if the outer sheath of a fiber optic pigtail is torn

What to do if the outer sheath of a fiber optic pigtail is torn

STEP 1) Taking care not to cause additional damage to the cable, use the scissors and side cutters to cut away pieces of severed sheath (Figure 2). STEP 2) Carefully scuff the cable sheath around the damaged section using a piece of medium grit sand-paper. Whether you're a network technician, IT professional, or telecom operator, you'll find practical steps, tools, and tips to restore connectivity with minimal loss. Dekam Fiber's state-of-the-art solutions, including our UltraRepair kits, make these processes accessible and reliable. This comprehensive guide outlines professional fiber optic repair protocols that align with industry best practices.

Read More
Should the fiber optic cable in the building be multimode or fiber optic

Should the fiber optic cable in the building be multimode or fiber optic

Single-mode or multimode fiber—these two options should be selected based on your budget, distance, and performance needs. Although they can do the same job in some instances, the different construction methods make each of them better suited to certain tasks and budgets. Two of the most common cable types you'll hear about when implementing a fiber network are single mode and multimode fiber. They both have their sweet spot, and knowing which one fits your organization's needs can help you make the right choice. This small diameter core, typically around 9 microns in diameter, allows only one mode of light to pass through, resulting in a narrower beam of light. While both serve the purpose of transmitting data through light pulses, they differ significantly in their characteristics, applications, and cost considerations.

Read More

Get In Touch

Connect With Us

📱

Poland (Sales & Engineering HQ)

+48 22 538 72 19

📍

Headquarters & Manufacturing

ul. Postępu 14, 02-676 Warszawa, Poland