PORTABLE MINERAL TESTERS FOR MINING AND EXPLORATION

Inspection Procedure for Relay Protection Testers

Inspection Procedure for Relay Protection Testers

Typical relay testing involves: Visual Inspection: Look for physical damage, corrosion, or loose connections. Insulation Resistance Test: Check insulation integrity to prevent leakage and short circuits. The testing and verification of relay protection devices can be divided into four groups: Type tests are needed to prove that a protection relay meets the claimed specification and follows all relevant standards. Most protective systems are fed from a current transformers on the supply cable or bus bars Inject PRIMARY current injection testing checks all current parts of the protection system by injecting the IP here test current through the primary circuit, of CT protective CTs.

Read More
Mining machine bandwidth 40G multimode fiber

Mining machine bandwidth 40G multimode fiber

OM3 and OM4 fibers were selected as the only multimode fiber for 40/100G consideration. The fibers are optimized for 850 nm transmission and have a minimum 2000 MHz∙km and 4700 MHz∙km effective modal bandwidth (EMB), respectively. The Cisco ® 40GBASE QSFP (Quad Small Form-Factor Pluggable) portfolio offers customers a wide variety of high-density and low-power 40 Gigabit Ethernet connectivity options for data center, high-performance computing 00networks, enterprise core and distribution layers, and service provider. Apart from the OM1 type, all of them are bending-optimized fiber incorporating technology to deliver enhanced macro-bending performance produced by a unique Plasma Chemical Vapor Deposition.

Read More
Mining and Fiber Optic Sensing Technology

Mining and Fiber Optic Sensing Technology

Recent advances in Distributed Optical Fiber Sensing (DOFS) technologies, particularly Brillouin Optical Time Domain Analysis (BOTDA) and Rayleigh Optical Frequency Domain Reflectometry (ROTDR), have opened new pathways for real-time, high-resolution monitoring in mining. The methodology involves embedding the sensing fiber into boreholes within the overlying strata and employing grouting to achieve effective coupling with the rock mass, a critical step that restores the in situ geological environment and ensures measurement reliability. Precise monitoring and early warning of these factors are essential for disaster prevention and control. A critical aspect of this management is ground control, focusing on addressing rock instabilities that arise from the mining processes and ore removal. In an era where mining operations strive to balance economic growth with safety and efficiency, the integration of Distributed Fiber Optic Sensing (DFOS) technology is reshaping the industry.

Read More
Grounding requirements for portable distribution boxes

Grounding requirements for portable distribution boxes

26 mm 2 (10 AWG) ground wire must be used, and in all other markets a 6 mm 2 must be used. Metal raceways, cable armor, and other metal enclosures for conductors shall be metallically joined together into a continuous electric conductor and shall be so connected to all boxes, fittings, and cabinets as to provide effective electrical continuity. Whether you're a seasoned pro or just starting out, this comprehensive guide will give you practical insights into proper grounding techniques, with a special focus on how selecting quality materials from a reliable building material supplier impacts your entire system's safety and longevity. Bonding is the intentional joining of normally non-current-carrying metallic components to form an electrically conductive path. Section 12, Installation and Maintenance of Equipment, Paragraph 123 Protective Grounding says in part: "Provisions must also exist for grounding during maintenance.

Read More

Get In Touch

Connect With Us

📱

Poland (Sales & Engineering HQ)

+48 22 538 72 19

🇪🇺

Germany (EU Technical Support)

+49 30 983 21 44

📍

Headquarters & Manufacturing

ul. Postępu 14, 02-676 Warszawa, Poland