PRACTICAL CHALLENGES OF INVERSE AND DEFINITE TIME OVERCURRENT ...

Practical Tips for Calculating Pigtail Quantity

Practical Tips for Calculating Pigtail Quantity

By experimenting you'll figure the right amount to strip, so that you don't leave exposed wires inside the box. A pigtail in electrical wiring is a short wire used to connect multiple wires to a single point or device. In the box on the right, the wires are pigtailed, yet still two wires bringing power in and two carrying power out to the next thing downstream. Also, it can join several wires to become a single conductor for electrical connections.

Read More
Common Faults of EXFO Optical Time Domain Reflectometers

Common Faults of EXFO Optical Time Domain Reflectometers

Large peaks on the OTDR trace suggest a high-reflectance event, often caused by air gaps, poorly seated connectors, or mismatched connector types. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, be it electronically, mechanically, or by any other means such as photocopying, recording or otherwise, without the prior writt eved to be accurate and reliable. OTDR fault diagnosis – Optical Time-Domain Reflectometers (OTDRs) help technicians locate and diagnose faults in fiber optic networks. Ensure the integrity of your fiber optic network with an Optical Time Domain Reflectometer (OTDR).

Read More
How to calculate the wiring time for PLC cabinets

How to calculate the wiring time for PLC cabinets

Following the traditional I/O wiring assembly process, it can take just over 46 minutes to wire and label a single I/O module. This doesn't take into account having to check for errors and effectively correct them. Connect the three phase wires from the bus bar to each of the circuit breaker inputs. What is a PLC Control Cabinet? A PLC control cabinet is an enclosure that organizes and protects automation devices. Because of cooling and ventilation overheating can be avoided which could reduce lifetime of components by half.

Read More
Exfo Optical Time Domain Reflectometer Test Module

Exfo Optical Time Domain Reflectometer Test Module

The EXFO FTB Lite 720D is a high-performance Optical Time Domain Reflectometer (OTDR) designed for testing and troubleshooting fiber optic networks. For fiber characterization, the testing equipment will need to measure/find the following key parameters: Insertion loss (IL): The loss of signal power expressed in decibels (dB) that results from the presence of an event on a fiber link, such as a splice or a connector. Buyer's Assurance Program - Test Equipment Center's strong technical service capabilities ensure meaningful warranty support is included for every item sold, protecting buyers in the rare case where a product failure occurs. Choose between :720D-SM1 = SM OTDR, 1310/1550 nm, 720D-SM8 = SM OTDR, 1310/1550 nm and 1650 nm live on single port, 720D-Q2-Q = QUAD OTDR, 850/1300 nm and 1310/1550.

Read More
Relay protection instantaneous overcurrent protection setting

Relay protection instantaneous overcurrent protection setting

IOCP settings depend on maximum short-circuit current and protection coverage, following IEC 60909 (short-circuit current calculation) and IEC 60255-151 (overcurrent protection settings). maxIi setting allows normal transient overcurrent inrush current for transformers: A 1st peak 10 to 25 x In Motor direct on line starting current: NOTE: MasterPacT MTZ1 L1 type circuit breakers are equipped with an additional fast instantaneous trip set at 10 x In. Overcurrent protection relay settings are critical for any electrical distribution system. The ANSI device number is 50 for an instantaneous overcurrent (IOC) or a Definite Time overcurrent (DTOC) and 51 for the Inverse Definite Minimum Time.

Read More